The anesthesia machine are used by anesthesiologists, nurse anesthetists to support the administration of anesthesia. It is designed to provide an accurate and continuous supply of medical gases (such as oxygen and nitrous oxide), which are mixed with an accurate concentration of anaesthetic vapour (such as isoflurane), and then delivered to the patient at a safe pressure and flow.
Basic Features:
Safety:
*AN300 Anesthesia Ventilator is outside the frame
Ventilation Modes | Flow meter | Flow meter | Tidal volume (Vt) | Frequency (Freq) | I/E |
---|---|---|---|---|---|
IPPV, Manual | O2(0.1-10L/min) N2O(0.1-10L/min) |
(0.1-10L/min) | 50 - 1600ml | 1-90bpm | 4:1 -6:1 |
Basic Features:
Safety:
*AN305 Anesthesia Ventilator is inside the frame
Ventilation Modes | Flow meter | Flow meter | Tidal volume (Vt) | Frequency (Freq) | I/E |
---|---|---|---|---|---|
IPPV, Manual | O2(0.1-10L/min) N2O(0.1-10L/min) |
(0.1-10L/min) | 50 - 1600ml | 1-90bpm | 4:1 -6:1 |
Standard Features:
Optional : O2, N2O Yoke device. When main gas supply fails, the backup gas supply starts.
Feature : | |
---|---|
Patient type : | Adult, Pediatric |
Driven mode : | Pneumatically driven electronically controlled |
Mode : | Semi-open, Semi-closed or Closed system |
Anesthetic vaporizer : | One vaporizer |
Power supply : | 220V+/-10%, 50Hz+/-1Hz |
Power consumption : | Not more than 50W |
Internal battery : | DC12V (over 4 working hours) |
Anesthesia Ventilator Specification : | |
Respiration mode : | IPPV, SIMV, SIGH, MANUAL |
Waveform : | P-t, V-t |
Tidal volume : | 50ml~1600ml |
Respiratory frequency : | 1~65 BPM / I: E ratio: 8: 1~1: 8 |
Alarm parameters : | High pressure alarm, Low pressure alarm, O2 source failure alarm |
High pressure alarm limit: | 20~60CMH2O / Low pressure alarm limit: 0~20CMH2O |
Monitor parameters : | Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I: E ratio |
Safety valve pressure limit : | 6 Kpa |
Main Unit : | |
Circle absorber : | Compact Circle absorber Bellow : 0 ~ 1600ml |
Flow meter : | O2, N2O four-tube flow meter O2 tube: 0L/min~1L/min~10L/min N2O tube: 0L/min~1L/min~10L/min O2 and N2O linkage device |
Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) | |
Oxygen Flush : | 25L/min ~ 75L/min |
Gas source pressure : | O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa |
Gauge : | 2 units, one N2O, one O2 |
Standard Features:
Optional : O2, N2O Yoke device. When main gas supply is fails, the backup gas supply starts.
Feature : | |
---|---|
Patient type : | Adult, Pediatric Driven mode : Pneumatically driven electronically controlled |
Mode : | Semi-open, Semi-closed or closed system |
Anesthetic vaporizer : | One high precise Vaporizers |
Power supply : | 220V±10%, 50Hz±1Hz |
Power consumption : | <50W |
Internal battery : | DC12V (over 2 hours) |
Anesthesia Ventilator Specification : | |
Respiration mode : | IPPV, SIMV, SIGH, MANUAL |
Waveform : | P-t, V-t |
Tidal Volume : | 50 ~ 1600ml |
Respiratory frequency : | 1 to 65 BPM |
I: E ratio: | 8: 1~1: 8 |
Alarm parameters: | High pressure alarm Low pressure alarm O2 source failure alarm AC power failure alarm |
High pressure alarm limit: | 20~60CMH2O |
Low pressure alarm limit : | 0~20CMH2O |
Monitor parameters : | Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I: E ratio, Airway pressure |
Safety valve pressure limit : | 6 Kpa |
Good air tightness, high reliability and minor respiration impedance | |
Main Unit : | |
Circle absorber : | Compact circle absorber |
Flow meter : | O2, N2O four-tube flow meter O2 tube: 0L/min~1L/min~10L/min N2O tube: 0L/min~1L/min~10L/min |
O2 and N2O Linkage Device: Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) | |
Oxygen Flush : | 25L/min ~ 75L/min |
Gas source pressure : | O2 : 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa |
Gauge : | Two gauges, N2O, O2 |
Standard Features:
Optional : O2, N2O Yoke device. When main gas supply is fails, the Backup gas supply starts.
Features : | |
---|---|
Application : | Adult, Pediatric |
Driven mode : | Pneumatically driven electronically controlled |
Mode : | Semi-open, Semi-closed or closed system |
Anesthetic vaporizer : | Two high precise vaporizers |
Power supply : | 220V±10%, 50Hz ±1Hz |
Internal battery : | DC12V (over 4 working hours) |
Anesthesia Ventilator Specification : | |
Waveform : | P-t, F-t |
Tidal Volume : | 50ml ~ 1600ml |
Respiratory frequency : | 1 ~ 65 bpm |
I: E ratio: | 4: 1~1: 4 |
Inspiration pause : | 0~55%Ti |
Trigger Pressure : | -20~20cmH2O |
Monitoring parameters : | O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, I:E ratio, Pmean, etc.. |
Pressure alarm setting : | High pressure alarm set 1~60cmH2O Low pressure alarm set 0~20cmH2O |
O2 concentration alarm setting: | high 21~99% low 21~50% |
MV alarm setting : | MV high alarm set 10~99L/min MV low alarm set 0~40L/min |
Main Unit: |
Circle absorber : | Compact circle absorber |
Flow meter : | O2, N2O four-tube flow meter O2 tube: 0L/min~1L/min~10L/min N2O tube: 0L/min~1L/min~10L/min |
O2 and N2O linkage device, keep oxygen concentration over 25% | |
Oxygen Flush : | 25L/min ~ 75L/min |
Gas source pressure : | O2 : 0.25MPa ~ 0.65MPa N2O : 0.25MPa ~ 0.65MPa |
Gauge : | 4 units, 2×N2O, 2×O2 |
Standard Features:
Optional : O2, N2O Yoke device. When main gas supply is fails, The backup gas supply starts.
Features : | |
---|---|
Application : | Adult, Pediatric |
Driven mode : | Pneumatically driven electronically controlled |
Mode : | Semi-open, Semi-closed or closed system |
Anesthetic vaporizer : | Two high precise vaporizers, Isoflurane, Enflurane, Halothane, Sevoflurane. |
Power supply : | 220V±10%, 50Hz ±1Hz |
Internal battery : | DC12V (over 4 working hours) |
Fresh gas outlet is in front of frame | |
Anesthesia Ventilator : | |
Respiration mode : | IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO |
Waveform : | P-t, F-t, V-t, F-v, V-p |
Tidal Volume : | 20~1600ml |
Respiratory frequency : | 1 ~ 65 BPM |
I: E ratio: | 4: 1~1: 4 |
Inspiration pause : | 0~55%Ti |
Inspiration Pressure : | 1~60cmH2O |
Trigger Pressure : | -20~20cmH2O |
Monitoring parameters : | O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I: E ratio, Pmean, etc. |
Alarm parameters : | High pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. |
Pressure alarm setting : | High pressure alarm set 1~60cmH2O Low pressure alarm set 0~20cmH2O |
O2 concentration alarm setting: | high 21~99% low 21~50% |
MV alarm setting : | MV high alarm set 10~99L/min MV low alarm set 0~40L/min |
Main Unit: |
Circle absorber : | Compact circle absorber |
Flow meter : | Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min. N2O tube: 0L/min~1L/min~10L/min. Air tube: 0L/min~10L/min O2 and N2O Linkage Device |
Keep oxygen concentration over 25% | |
Oxygen Flush : | 25L/min ~ 75L/min |
Gas source pressure : | O2 : 0.25Mpa ~ 0.65Mpa N2O : 0.25Mpa ~ 0.65Mpa Air: 0.25Mpa ~ 0.65Mpa |
Gauge : | 4 units, 2 x O2, N2 O, Air. |
Basic Features:
Optional : Patient monitor, Anesthetic gas monitor, AGSS, O2 /AIR blender, Hand held ETCO2 module.
Ventilation mode | IPPV (VCV)/A/C (SIPPV) SIMV / MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 0.2s - 6s 2:1 - 1:6 |
Tidal Volume VT | 0ml - 1500ml |
MV | >18L/min |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20 2O - 20cmH2O |
Ftr, Pc, TIP | - |
Apnea Ventilation | OFF,5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) " |
Basic Features:
Optional : Patient monitor, Anesthetic gas monitor, AGSS,Yoke, ACGO, ETCO2 module on screen.
Ventilation mode | IPPV (VCV) / A/C (SIPPV) SIMV / MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 0.2s - 6s 2:1 - 1:6 |
Tidal Volume VT | 0ml - 1500ml |
MV | >18L/min |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20 2O - 20cmH2O |
(Ftr), (Pc) , ( TIP) | (OFF,0.5L/min - 30L/min), (-), (0-3s) |
Apnea Ventilation | OFF,5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) " |
Same as AN314 but with Electronic Valve & Ventilation modes includes pressure control and volume control limit.
Ventilation mode | IPPV (VCV) / A/C (SIPPV) PCV SIMV SIGH MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 0s - 12s 4:1 - 1:8 |
Tidal Volume VT | 0ml - 1500ml |
MV | >18L/min(Adult) >10L/min(Children) |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20 2O - 20cmH2O |
Ftr | OFF, 1L/min - 30L/min |
Pc | 5cmH2O - 60cmH2O |
TIP | 0 - 6s |
Apnea Ventilation | OFF, 5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) 3. P-V loop (pressure – volume loop) |
Basic Features :
OPTIONAL: Patient monitor, Anesthetic gas monitor, AGSS, Yoke.
AN330A : Same as AN330 but with patient monitor
AN330B : Same as AN330A but with Anesthetic gas monitor, AGSS, Yoke-3.
Ventilation mode | IPPV (VCV) / A/C (SIPPV) PCV SIMV SIGH MANUAL |
Frequency | 1bpm - 100bpm |
I/E | 4:1 - 1:8(Adult) 2:1 - 1:8(Children) |
Tidal Volume VT | 0ml - 1500m |
MV | >18L/min(Adult) >10L/min(Children) |
PEEP | 0cmH2O - 30cmH2O |
PTr | -20cmH2 O - 0cmH2O |
Ftr | OFF, 0.5L/min - 30L/min |
Pc | 5cmH2O - 60cmH2O |
TIP | 0 - 6s |
Apnea Ventilation | OFF, 5s - 60s |
SIGH | 1/100 - 5/100 |
Graphical display | 1. P-T(pressure – time) 2. F-T(flow – time) 3. P-V loop (pressure – volume loop) 4. V-T(volume – time ) 5. ETCO2 -T (End-tidal Co2 - time) |