Infusion Pump



DP2070 - Perfusor Compact

Standard Features:

  • All standard syringes of 10ml\20ml\50ml are compatible. The machine diagnoses the syringe size automatically, and with a simple syringe specification setting, the syringe pump can guarantee an accurate and safe injection.
  • Unique function of bedside injection supervision which makes patients and their relatives as well as nurses more assured.
  • Excellent injection function and operation. Even small-volume injection is accurate.
  • Double CPU system ensures safe and reliable injection process.
  • Driven by precision step motor, no pulsating waves shall occur during even low-rate injection.
  • Accurate and sensitive pressure sensor detects occlusion pressure accurately.
  • Alarms are given in case of malfunction or operation error and the machine stops operation automatically.
Specifications:
  • Feasible injection rate range:10ml:0.1-100ml/h
  •     20ml:0.1-200ml/h
        50ml:0.1-500ml/h
  • Maximum power consumption: 25VA,running more than 5h after being fully charged.
  • Injection increment: 0.1ml/h
  • Injection accuracy: ±3%
  • Bolus: The fastest rate of the size of syringe in use
  • Displayed information: Rate, accumulated injection volume, Syringe size Battery capacity, Bed No., AC power indicator, Battery charge indicator.
  • Accumulated injection volume: 0-999.9ml
  • Alarm functions: Near, Over, OCCL., low battery, syringe installation error, control abnormal, machine malfunction
  • Electrical safety: Comply with the requirement of GB9706.1-1995, EN60601-1and UL60601-1
  • EMC(Electromagnetic compatibility); Comply with the requirement EN60601-1-2,EN60601-2-24
  • Power supply: 50/60Hz AC100V-240V
  • Maximum weight: <3.0kg

DP2075A - Infusion Pump

Basic Features:

  • 25" LCD monochrome screen 132 x 32 pixels.
  • Embedded handle, Vertical pole mount.
  • Highly accurate infusion rate.
Technical Features
Code DP2075A
Infusion set Applicable to GB 8368-2005 disposals; diameters Ø3.5-4.5mm, thickness 0.8-1.2mm
infusion mode Rate mode
Bolus 600 ml/h
Flow rate 0.10-1500ml/h
Volume Limit 0.1~9999ml
Accuracy < ± 5%
KVO rate 0.5 ml/h
Occlusion Low 150-125 mmHg (20k Pa): Medium 525± 125 mmHg (70kPa) High 900±180 mmHg (120kPa)
Air bubble detection Single bubble detection 50, 100, 250, 500 800l μl Accumulated bubble detection: 0.1-4.0ml/h, adjustable
Titration Yes, increment is 0.1 ml/h
AC power 100-240V (50/60Hz, 0.4-0.14A)
DC power 10-16V (2.25-1.5A)
Battery type Lithium
Battery operation time >4 hours @ 25ml/h
Charging time <6 hours @100%
Classification CF, Class I
IP Grade IP 34
Temperature 5~40°C for operating, -20~60°C for storage
Humidity 15~95% for operating, 10~95% for storage
Air pressure 57~106 kPa for operating, 50~106kPa for storage
Weight <1.6 kg (not including clamp)
Dimension 146 x 193 x 95 mm

DP2080 - Spirometer

Standard Features:

  • Designed for daily home healthcare and clinique
  • Light weight and portable size
  • 1.8" sw160x128 TFT display, led backlight.
  • Simple operation and rapid test.
  • Basically analyze and state explain.
  • Provide rate-volume and volume-time waveform used for diagnosing to doctor
  • Inner flash memory for data storage, and the storage data can be uploaded to computers.
    (used USB or wireless manners)
  • Power capacity indication and automatic power off in 1 minute.
Specifications:
  • Max volume: 10L
  • Flow range: 16L/s
  • Volume accuracy: ±3% or 50ml
  • Flow accuracy: ±5% or 200ml/s
  • Battery: built-in lithium battery (DC 3.7V)
  • Dimension: 97mm(L) × 89mm(W)× 36mm(H)
  • Netweight: 150g

DP2085 - Volumetric Pump

Basic Features:

  • Horizontal design LCD Display
  • Accurate fluid delivery
  • Infusion speed adjustable.
  • Built in rechargeable lithium battery
  • Alarm for 12 function.
Technical Features
Flow rate 0.1~1500 mL/h (0.1 mL/h step, if the value is 100 mL/h or above, the step is 1mL/h )
Bolus rate 600~1000 mL/h (Adjustable)
KVO rate 0.1 mL/h~5 mL/h (Adjustable)
Accuracy of infusion <±5%(<±3% for calibrated infusion apparatus)
Bubble detector Ultrasonic detection method
Detection sensitivity 25 micro L
Infusion history records 1500 pcs
Preset volume 1~9999 mL
Display range of totally delivered volume 0~9999 mL(0.1 mL step, if the value is above 100 mL, the step is 1 mL )
Power Built in battery: DC12 V, 2300mAH,in fully charged status, the device can work for more than 6 hours at the rate of 25mL/h

DP2085-SH - Volumetric Pump

Basic Features:

  • Compact and light weight design
  • Various infusion modes
  • Anti-reverse rotation detection Various visual and audible alram
  • Real Time Display
  • Free flow protection Double CPU ensuring safe infusion
  • Removable pump body for conveinet cleaning
Technical Features
Bolus 300 ~ 1200 ml/h
Flow rate range 0.1~1200 ml/h
Volume limit 1-9999 ml
Accuracy ±5%
KVO flow rate 1 ~ 5 ml/h
Power supply AC100-240V, 50/60 Hz, 25VA
Battery Rechargeable lithium polymer battery, 7.4 V, 1650mAh
Power 25VA
Weight 1.6 Kg
Dimension 145×100×120 mm
Infusion mode Rate mode, drip mode, time mode, body weight mode