Infant Resuscitation Trolley, Baby Bassinet - Apple Series



NIC1005 - Mouth to Mask Resuscitation
  • An ideal solution is to manage PPV in a simplest and safest way. Blow SafeTM is a scientific device designed to deliver PPV with pressure release valve and can be easily used by any Health Care personal. Autoclavable silicone corrugated extension tubing, polycarbonate one-way non-breathing valve, pressure release valve and silicone face mask makes the devices to be used in any ruff-n-tuff condition.
  • Mouth Piece Silicone Corrugated Autoclavable Extension Tubing. The corrugate section prevents blockage of air inlet even when the tubing is in bending position. Due to high volume it creates sufficient pressure than ordinary tubing.
  • Safety Pressure Release Valve One-Way Non-Rebreathing Valve This prevents mixing of inhaled and exhaled air.
  • Silicone Face Mask This provides air tight sealing above nose and mouth. Size: 01

NIC1010 - Infant Resuscitation Kit

An Essential Carrying Kit for providing Effective Resuscitation to an Infant.(Available in a Carry Bag).

Contents of the Kit Infant Resuscitator, Foot Suction, Laryngoscope, Airways.

Infant Resuscitator:
  • Rugged; 100% Autoclavable; Reusable.
  • 250 ml silicone bellow with Non rebreathing valve
  • Mask sizes : No. 00 & 01.
  • 360° swiveling patient connector with standard 15 mm / 22 mm diameter.
  • Corrugated PVC oxygen reservoir.
  • 1.5 mtr. PVC oxygen tubing.
Foot Suction:
  • Compact, light weight, easy to handle and operate.
  • Durable rubber bellow.
  • Long lasting stainless spring to provide friction free pumping.
  • Completely autoclavable polycarbonate vacuum jar with lid (500 ml capacity).
  • Scratch proof powder coated frame.
Laryngoscope :
  • Stainless steel straight blades of size 0 & 1 with penlight handle.
Airways :
  • Silicone, autoclavable & reusable in sizes 000, 00 & 0.

NIC1015 - Child Resuscitation Kit

An Essential Carrying Kit for providing Effective Resuscitation to a Child.(Available in a Carry Bag).

Contents of the Kit Child Resuscitator, Foot Suction, Laryngoscope, Airways.

Child Resuscitator:
  • Rugged 100% Autoclavable; Reusable
  • 500 ml silicone bellow
  • Non rebreathing valve with 40 cm of H2O pressure release
  • Mask sizes : No. 01 & 02
  • 360° swiveling patient connector with standard 15mm/ 22mm diameter
  • Corrugated PVC oxygen reservoir
  • 1.5 mtr. PVC oxygen tubing
Foot Suction:
  • Compact, light weight, easy to handle and operate
  • Durable rubber bellow
  • Long lasting stainless spring to provide friction free pumping
  • Completely autoclavable polycarbonate vacuum jar with lid (500 ml capacity)
  • Scratch proof powder coated frame
Laryngoscope:
  • Stainless steel straight blades of size 0 & 1 with penlight handle.
Airways:
  • Silicone, autoclavable & reusable in sizes 000, 00 & 0.

NIC250a - Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 4 modes Skin/Air/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" wheel
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy. Three drawer for storage.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
Dimensions :
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Air Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Air, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C , Resolution : 0.1°C
  • Air mode: Temperature range: Room temp. to 39°C , Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz
  • Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC251a - Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 3 modes Skin/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" wheel
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy. Three drawer for storage.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
Dimensions :
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C, Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz, Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC260a - Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 4 modes Skin/Air/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" wheel
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy. Three drawer for storage.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
Dimensions :
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Air Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Air, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C , Resolution : 0.1°C
  • Air mode: Temperature range: Room temp. to 39°C , Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz
  • Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC261a - Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 3 modes Skin/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" wheel
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy. Three drawer for storage.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
Dimensions :
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C, Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz, Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC270 - Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 4 modes Skin/Air/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" (100mm) wheels, 2 with brake
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy. Three drawer for storage.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Air Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Air, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C , Resolution : 0.1°C
  • Air mode: Temperature range: Room temp. to 39°C , Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz
  • Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC271 - Resuscitation Unit with Fixed Baby Cradle & Drawers with Microprocessor based temperature controller with 3 modes Skin/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" (100mm) wheels, 2 with brake
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy. Three drawer for storage.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C, Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz, Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC275 - Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 4 modes Skin/Air/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" (100mm) wheels, 2 with brake
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
Dimensions :
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Air Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Air, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C , Resolution : 0.1°C
  • Air mode: Temperature range: Room temp. to 39°C , Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz
  • Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC276 - Resuscitation Unit with Fixed Baby Cradle with Microprocessor based temperature controller with 3 modes Skin/Manual/Prewarm Mode
Mechanical Specifications :
  • Fixed height warmer with attached baby cradle mounted on 4" (100mm) wheels, 2 with brake
  • Stainless steel baby tray with water proof, zipped cover mattress of density approx. 21-25 kg/m³
  • Continuous head up/down facility
  • X-Ray cassette holder
  • Collapsible/lockable Side Supports made up of Unbreakable polycarbonate material
  • Slots for sensor and ventilator tubing
  • Side tray for placement of monitor
  • Stainless steel infusion rod with facility to mount Syringe/infusion pump
  • Lower shelf below baby tray to facilitate under surface phototherapy.
  • Integrated support for 10L Oxygen bottle.
  • Oxygen regulator with pressure gauge, flow meter and humidifier bottle along with silicon tubing for delivery of oxygen from humidifier bottle to patient.
  • Integrated electrical operated Slow Suction unit with Vacuum Regulator, Vacuum Gauge and autoclavable fluid jar.
  • Silicone manual Resuscitator for Infant (250ml) along with face masks size 00 and 01.
  • Laryngoscope - Penlight handle with straight blade size 0 and 1.
  • Silicone Airways - size 000, 00, and 0
Dimensions :
  • Height : 74.5" (1890 mm), Width : 28.0" (710 mm), Length : 39.0" (990 mm)
  • Bed to Floor Height : 37.5" (950 mm)
  • Distance between baby bed and heater: 33" (840 mm)
  • Mattress size: 30" (762 mm) x 20" (508 mm)
  • Height of side panel above baby bed: 5.75" (145 mm)
Performance/Electrical Specifications :
  • Microprocessor based temperature controller with Pre-warm, Manual and Skin Servo modes
  • LED Display of Skin Temp., Set Temp. (Resolution 0.1°C) & Heater Power %.
  • LCD to display modes of operation, Alarm messages, Skin Temperature in °F and Timer.
  • Thermistor based sensor with Accuracy of +/- 0.2°C (Temp. Calibration not require)
  • Modes of Operation: Skin Servo, Manual and Pre-Warm
  • Keypad lock facility
  • Skin mode: Temperature range: 34 to 38°C, Resolution : 0.1°C
  • Manual mode: Adjustable Heater Power 0 to 100% (with an increment of 5%), Time duration:15mins
  • Pre-warm mode: To pre-warm the cradle before baby is placed on the bed. (No alarm will be activated during Prewarm mode) Adjustable Heater Power 0 to 25% (with an increment of 5%), Time duration:30mins
  • Overhead heater box: Swivelling, Consists of Ceramic heater (650 Watts) placed in parabolic reflector with a safety grill & Halogen observation light (12V/50W) for observing the baby
  • Operating Voltage: 220-240 VAC, 50Hz, Power: 800W (Max.)
  • Alarm: Audio alarm with 10 minute mute facility & Visual alarms with message on LCD
  • Power Fail Alarm: Audio with LED indicator

NIC1016 - Adult Resuscitation Kit

An Essential Carrying Kit for providing Effective Resuscitation to a Adult.(Available in a Carry Bag).

Contents of the Kit Adult Resuscitator, Foot Suction, Laryngoscope, Airways.

Adult Resuscitator:
  • Rugged 100% Autoclavable; Reusable
  • 1600 ml silicone bellow with Non rebreathing valve
  • Mask sizes : No. 03 & 05
  • 360° swiveling patient connector with standard 15mm/ 22mm diameter
  • Corrugated PVC oxygen reservoir
  • 1.5 mtr. PVC oxygen tubing
Foot Suction:
  • Compact, light weight, easy to handle and operate
  • Durable rubber bellow
  • Long lasting stainless spring to provide friction free pumping
  • Completely autoclavable polycarbonate vacuum jar with lid (500 ml capacity)
  • Scratch proof powder coated frame
Laryngoscope:
  • Stainless steel curved Machintosh blades of size 3 & 4 with standard handle
Airways:
  • Silicone, autoclavable & reusable in sizes 1, 2 & 3.

Emergency Medical Care 24/7

With access to 24 hour emergency assistance, It’s so important you can continue to help others.